Unit 2 Gable Business Park, 10 Derrick Drive, Somerset West, 7130
XT H 225 ST 2x thumb
XT H 225 ST 2x thumb
XT H 225 ST 2x thumb

XT H 225 ST 2x Industrial CT Scanning

The XT H 225 ST is a Computed Tomography (CT) system ideally suited to a wide range of materials and sample sizes, especially those that are too large or heavy for other systems in the range. The system has three interchangeable sources; the 225 kV reflection target, 180 kV transmission target and the optional 225 kV rotating target. Combined with the wide range of flat panel detectors to choose from, the ST system provides a flexible tool for quality laboratories, production facilities and research departments.

Key benefits

XT H 225 ST 2x Key features

Flexibility When You Need It

With the choice of source, targets, CT scanning strategies and options such as motorised source-to-detector distance adjustment, the XT H systems are versatile and accommodate a wide range of inspection tasks.

X.Tend Helical CT

Tall objects can be scanned in a single acquisition process, eliminating artifacts introduced by the cone beam and multi-scan stitching. This also provides the added benefit of scanning objects at higher magnification resulting in significantly higher resolution.

Unique 225 kV Rotating.Target 2.0

Nikon Metrology industrial CT systems uniquely offer the benefit of using rotating target technology to increase
scanning speed and signal-to-noise ratio dramatically. It is due to the target’s ability to generate high power X-rays
while maintaining a small focal spot. Optimisation of the design of the latest version, Rotating.Target 2.0, has enabled a
doubling of the guaranteed operating time.

Auto.Filament Control

With the XT H 225 ST 2x, the user no longer has to choose
between high-resolution and long-life filaments. Auto.
Filament Control intelligently controls the X-ray source to
double the lifetime of the filament and increase system
availability.

Half.Turn / Tilted CT acquisition mode

Instead of rotating the sample under investigation through 360 degrees while the X-rays directed at it are either absorbed
or pass through to the detector, Nikon Metrology has devised a method that allows sufficient data to be obtained by
rotating the sample through just over 180 degrees.

Using an angled axis of rotation, Titled CT is an X-ray
laminography technique allowing planar, flat and high-aspect
ratio components to rotate closer to the X-ray source than
conventional CT. This vastly increases voxel resolution, improves
magnification and produces high-resolution 3D volumes from
thousands of 2D X-ray images.

Low cost of ownership
The open X-ray tube allows for local maintenance of internal tube components. The 3-wheel transportation incorporated allows the system to easily be manoeuvred through double-door entries. Also no special floor treatment is required to install XT H 225.

 

XT H 225 ST 2x Specifications

XT H 225 ST specs

X-ray Source
Type Open Tube Microfocus
Target Options Reflection Target
Rotating Target 2.0
Transmission Target
Multimetal Target
Maximum Energy 225 kV
Maximum Power 450 W
Minimum Focal Spot 1 μm
System
Maximum CT Swept Diameter 265 mm
Maximum FID (Focus-Imager-Distance) 1,110 mm nominal
FID Type Motorised moveable
Maximum Sample Weight 50 kg
Detector
Maximum Active Area 432 mm x 432 mm
Maximum Pixel Matrix 2,880 x 2,880
Minimum Pixel Size 150 μm
Maximum Frame Rate 30 fps
Type ASTM E 2597
Cabinet
Length 2,414 mm
Width 1,275 mm
Height 2,202 mm
Weight 4,200 kg

 

 